APPS Logo Contents
Previous Next PDF

A COMPARISON OF TEMPERATURE REGULATION, FLUID EXCHANGE AND HEART RATE RESPONSE BETWEEN TWO LOAD BEARING SYSTEMS

C.L. Lim, Y.M. Tan, Y.N. Teo and M.C. Yap, Military Physiology Lab, Defence Medical Research Institute, Singapore.

We evaluated temperature regulation and fluid exchange of first-year soldiers wearing two webbing and full-pack systems. Twelve volunteers performed two repeated trials wearing the current webbing (SBOcr) comprising of strap based system and a new vest webbing system (SBOnw). They were separated into two groups walking at speeds of 4km·hr-1 (n=7) and 5km·hr-1 (n=5) on a treadmill. The trials were conducted in a climatic chamber (33°C dry bulb; 65% RH; 850 W·m2 radiation). They walked for two cycles of 60 min, with 15 min of rest. Another group of N=18 volunteers performed the trials wearing the webbing and with the respective current (FBOcr) and new (FBOnw) full-pack system. They performed trials at walking speeds of 3.5km·hr-1 (n=12) and 5km·hr-1 (n=6). Core temperature (Tc) in SBO trial ranged between 37.1±0.4°C and 39.1±0.4°C (SBOcr) and between 37.1±0.5°C and 38.9±0.2°C (SBOnw). There was no significant difference in mean Tc between SBOcr and SBOnw trials (P>0.05). In the FBO trial, Tc ranged between 37.1±0.5°C and 38.8±0.7°C (FBOcr) and between 37.0±0.5°C and 39.1±0.5°C (FBOnw). No statistical significance was reported. Mean heart rate (HR) in SBOcr trial ranged between 115±11bpm and 168±21bpm in the first cycle and between 125±29bpm and 169±17bpm in the second cycle. In the SBOnw trial, mean HR ranged between 108±19bpm and 165±19bpm in the first cycle and between 120±27bpm and 158±10bpm in the second cycle. Although not significantly different, the SBOcr trial recorded 5 to 11bpm higher mean HR in the second cycle compared to the SBOnw trial. It could be concluded that the subjects needed greater physical effort to move with the SBOcr system after some degree of fatigue had set in. Mean fluid intake in the SBO trials was 1.77±0.5L (SBOcr) and 1.89±0.6 L (SBOnw). In the FBO trials, mean fluid intake in the FBOcr and FBOnw trials were 1.95±0.53L and 2.35±0.61L respectively. The FBO system resulted in higher fluid intake compared to the FBOcr trial. Mean sweat rate (SR) in all the trials, including current and new load-bearing system (LBS), ranged between 16ml·hr-1 and 19ml·hr-1, except for the two SBO trials at 5km·hr-1 which had means SR of 25ml·hr-1 and 26ml·hr-1. The present study has found the LBSnw system to be an improvement to the LBScr system in terms of weight distribution. The volunteers responded similarly to both to the LBS systems for all factors, except for higher heart rate in the SBOcr trial, and they felt cooler when using the LBScr system. The level of heat stress was found to be similar between the two systems. The advantage of this study provided comparisons of the thermoregulatory responses to the existing and new webbing systems worn by the soldiers.

Figure

nmiv1@nus.edu.sg